Custom Stainless Enclosures, Inc. » 4Xxtreme® Series Enclosures » Multi Door Enclosures Hygienic Multi Door Enclosures Enhance your equipment protection with our 4Xxtreme® Hygienic Multi Door Enclosures. These custom stainless enclosures are designed to provide peace of mind for safeguarding your equipment in various challenging indoor and outdoor settings. Adding multiple doors allows for easy access to different sections of the enclosure, improving maintenance efficiency and equipment management. The hygienic design ensures a clean and secure environment for your equipment, vital in sanitary production settings. Protect your equipment from falling dirt, dust, oil, and water to ensure the longevity and reliability of your controls, terminals, and instruments, including electrical, hydraulic, and pneumatic systems. REQUEST A QUOTE PART # CUTSHEET Similar Products: Flanged Multi Door Enclosures Sequester Flanged Multi Door Enclosures Twin Door Enclosures Custom Stainless Enclosures, Inc. » 4Xxtreme® Series Enclosures » Multi Door Enclosures Hygienic Multi Door Enclosures Enhance your equipment protection with our 4Xxtreme® Hygienic Multi Door Enclosures. These custom stainless enclosures are designed to provide peace of mind for safeguarding your equipment in various challenging indoor and outdoor settings. Adding multiple doors allows for easy access to different sections of the enclosure, improving maintenance efficiency and equipment management. The hygienic design ensures a clean and secure environment for your equipment, vital in sanitary production settings. Protect your equipment from falling dirt, dust, oil, and water to ensure the longevity and reliability of your controls, terminals, and instruments, including electrical, hydraulic, and pneumatic systems. REQUEST A QUOTE PART # CUTSHEET Superior Design Double Seal™ Gasketing Technology Field-replaceable gasket system Foreign material inspectable Ultra Clean – Free Draining Design 7° Hygienic Pitch on all top and bottom of doors Pitched outer seal gasket for full drainage Weld-on bullet hinge assembly Lift-off door 180° door swing Manufactured from 14-gauge or 12-gauge 304 or 316 SS material All outside weld seams are continuously welded and ground smooth Double Stud® Mounting Technology Innovative mounting system that eliminates gaskets and reduces overall installation time Removable Center Post Hygienic Pitched Top Configurations We offer the most extensive range of electrical enclosure top configurations in the industry Slope Forward (Slope 7° to 30°) Slope Back (7° to 22°) Bullnose Slope Forward (7° to 30°) Bullnose Slope Back (7° to 30°) Flat Top Single 316 SS Three-Point Latching Hygienic quarter turn Master Defeater and Slave handles Superior Design Double Seal™ Gasketing Technology Field-replaceable gasket system Foreign material inspectable Ultra Clean – Free Draining Design 7° Hygienic Pitch on all top and bottom of doors Pitched outer seal gasket for full drainage Weld-on bullet hinge assembly Lift-off door 180° door swing Manufactured from 14-gauge or 12-gauge 304 or 316 SS material All outside weld seams are continuously welded and ground smooth Double Stud® Mounting Technology Innovative mounting system that eliminates gaskets and reduces overall installation time Removable Center Post Hygienic Pitched Top Configurations We offer the most extensive range of electrical enclosure top configurations in the industry Slope Forward (Slope 7° to 30°) Slope Back (7° to 22°) Bullnose Slope Forward (7° to 30°) Bullnose Slope Back (7° to 30°) Flat Top Single 316 SS Three-Point Latching Hygienic quarter turn Master Defeater and Slave handles Limitless Features Fully customize your multi door enclosure with limitless options including: Mechanically interlocked door system Hygienic Leg Assemblies – 316 SS material Sequester enclosure Trapped Key Interlock Exchanged Unit & Convenience Enclosure Heavy-Duty Lifting Eyes – 316 SS material Hygienic Windows: Polycarbonate, Acrylic, or Thermal – Type 4X, IP66, IP68, and IP69K rated Center divider available to separate low voltage from high voltage Grounding provisions are provided on all doors and enclosures Drilled and tapped back panels Back panels are available in 12 Gauge G90 Galvanized, Aluminum, Stainless Steel, and Powder Coated Hygienic Operator interface swivel arm assemblies – Type: 4X, IP66, IP68, and IP69K Floor mount configuration Double Stud® hygienic mounting brackets: Bolt-on 1, 2, 4 & 10” off wall Double Stud® hygienic mounting extensions: 1, 2, and 3” Limitless Features Fully customize your multi door enclosure with limitless options including: Mechanically interlocked door system Hygienic Leg Assemblies – 316 SS material Sequester enclosure Trapped Key Interlock Exchanged Unit & Convenience Enclosure Heavy-Duty Lifting Eyes – 316 SS material Hygienic Windows: Polycarbonate, Acrylic, or Thermal – Type 4X, IP66, IP68, and IP69K rated Center divider available to separate low voltage from high voltage Grounding provisions are provided on all doors and enclosures Drilled and tapped back panels Back panels are available in 12 Gauge G90 Galvanized, Aluminum, Stainless Steel, and Powder Coated Hygienic Operator interface swivel arm assemblies – Type: 4X, IP66, IP68, and IP69K Floor mount configuration Double Stud® hygienic mounting brackets: Bolt-on 1, 2, 4 & 10” off wall Double Stud® hygienic mounting extensions: 1, 2, and 3” Enclosures for All Industries A solution that meets the demands of all industries maintaining optimal performance and reliability. From heavy industry to high-tech laboratories, our enclosures are designed to meet the unique challenges of your electrical equipment. Enclosures for All Industries A solution that meets the demands of all industries maintaining optimal performance and reliability. From heavy industry to high-tech laboratories, our enclosures are designed to meet the unique challenges of your electrical equipment. Locations of disconnects and requirements for proper disconnect spacing are determined by the purchaser. Consult Space Occupied by Disconnect drawing to determine whether or not the disconnect device you are using will fit the enclosure size that you have selected for the application. Refer to the current National Electrical Code 2008 article 430.10(B) for wiring space required for the size of conductors to be connected to disconnect. Always verify your application to determine if the wiring space is adequate before drawing approvals. Custom Stainless Enclosures, Inc. is not responsible for verifying flange design, with customer’s disconnect and or enclosure sizes.